Example infrastructure outage incident report Friday, May 13, 2077 By the Example Security Team Earlier this week we experienced an outage in our API infrastructure. Today we’re providing an incident report that details the nature of the outage and our response. The following is the incident report for the Example Security outage that occurred on April 30, 2077. We understand this service issue has impacted our valued developers and users, and we apologize to everyone who was affected.

Issue Summary From 6:26 PM to 7:58 PM PT, requests to most Example Security APIs resulted in 500 error response messages. Example Security applications that rely on these APIs also returned errors or had reduced functionality. At its peak, the issue affected 100% of traffic to this API infrastructure.

Users could continue to access certain APIs that run on separate infrastructures. The root cause of this outage was an invalid configuration change that exposed a bug in a widely used internal library. Timeline (all times Pacific Time) 6:19 PM: Configuration push begins 6:26 PM: Outage begins 6:26 PM: Pagers alerted teams 6:54 PM: Failed configuration change rollback 7:15 PM: Successful configuration change rollback 7:19 PM: Server restarts begin 7:58 PM: 100% of traffic back online Root Cause At 6:19 PM PT, a configuration change was inadvertently released to our production environment without first being released to the testing enviroment. The change specified an invalid address for the authentication servers in production.

Incident Report. Report Date/Time: January 1, 2004 / 11:00 AM Confidentiality. Distribution of this document is limited to Company Department. Applied Differential Equations Spiegel Pdf Creator. Access should only be granted to those with a business related need-to-know. If you have any questions pertaining to the distribution of this document, please contact John Smith. Outage reporting in IT needs to be more thorough and public so that we may avoid know problems, mistakes, and pitfalls. Many outages. There are several examples of formalized or regular places to share incident reports, though sadly, most of them outside of the information & communications industry.

This exposed a bug in the authentication libraries which caused them to block permanently while attempting to resolve the invalid address to physical services. In addition, the internal monitoring systems permanently blocked on this call to the authentication library. The combination of the bug and configuration error quickly caused all of the serving threads to be consumed. Traffic was permanently queued waiting for a serving thread to become available. The servers began repeatedly hanging and restarting as they attempted to recover and at 6:26 PM PT, the service outage began. Resolution and recovery At 6:26 PM PT, the monitoring systems alerted our engineers who investigated and quickly escalated the issue.

By 6:40 PM, the incident response team identified that the monitoring system was exacerbating the problem caused by this bug. At 6:54 PM, we attempted to rollback the problematic configuration change. This rollback failed due to complexity in the configuration system which caused our security checks to reject the rollback. These problems were addressed and we successfully rolled back at 7:15 PM. Some jobs started to slowly recover, and we determined that the overall recovery would be faster by a restart of all of the API infrastructure servers globally. To help with the recovery, we turned off some of our monitoring systems which were triggering the bug. As a result, we decided to restart servers gradually (at 7:19 PM), to avoid possible cascading failures from a wide scale restart.

By 7:49 PM, 25% of traffic was restored and 100% of traffic was routed to the API infrastructure at 7:58 PM. Corrective and Preventative Measures In the last two days, we’ve conducted an internal review and analysis of the outage.

The following are actions we are taking to address the underlying causes of the issue and to help prevent recurrence and improve response times: Disable the current configuration release mechanism until safer measures are implemented. (Completed. Zemana Antilogger Serial Downloads on this page. ) Change rollback process to be quicker and more robust. Fix the underlying authentication libraries and monitoring to correctly timeout/interrupt on errors.

Downtime Incident Report Template

Programmatically enforce staged rollouts of all configuration changes. Improve process for auditing all high-risk configuration options. Add a faster rollback mechanism and improve the traffic ramp-up process, so any future problems of this type can be corrected quickly. Develop better mechanism for quickly delivering status notifications during incidents. Example Security is committed to continually and quickly improving our technology and operational processes to prevent outages. We appreciate your patience and again apologize for the impact to you, your users, and your organization.